3D Viewer

SATK30103

Wall-mounted indirect heat interface unit

Manufacturer CALEFFI

Satk Series
Wall-mounted indirect heat interface unit complete with:
Heating (set point regulation)
- brazed exchanger (Pnom 15 kW);
- 2-way primary modulating valve (max. Δp 0.9 bar)
- safety valve 3 bar
- flow temperature probe
- safety sensor
- heat meter template code 755404K / 755405K
- expansion vessel 7 l
- Pump with protective by-pass
- filling unit
- pressure switch
Low temperature range: 25-45°C.
Medium/high temperature range: 50-75°C.

DHW production 
- brazed exchanger 40 kW
- modulating valve on primary side exchanger (max Δp 0.9 bar)
- DHW temperature probe
- DHW priority flow meter DHW temperature range: 42-60°C (max 18 l/min)
- Electronic regulator
Functions which can be activated
• Modulating temperature regulation with compensated set point:    
low temperature (Adjustment SET ±5 °C)   
medium temperature (Adjustment SET ±10 °C)
• DHW exchanger preheating
Max. working pressure: primary 16 bar.                            
                                      secondary heating  3 bar.                           
                                      DHW secondary 10 bar.
Power supply: 230 V – 50 Hz
Power consumption: 75 W.

Dimensions

(l x h x p): 550 x 630 x 265 mm

Related products

 - Wall-mounted indirect heat interface unit SATK30105 - CALEFFI Wall-mounted indirect heat interface unit Wall-mounted indirect heat interface unit complete with:
Heating (set point regulation)
- brazed exchanger (Pnom 15 kW);
- 2-way primary modulating valve (max. Δp 0.9 bar)
- safety valve 3 bar
- flow temperature probe safety sensor
- heat meter template code 755404K / 755405K
- expansion vessel 7 l
- Pump with protective by-pass
- filling unit
- pressure switch
Low temperature range: 25-45°C.
Medium/high temperature range: 50-75°C.

DHW production 
- brazed exchanger 65 kW
- modulating valve on primary side exchanger (max Δp 0.9 bar)
- DHW temperature probe
-DHW priority flow meter
DHW temperature range: 42–60°C (max 25 l/min).
- Electronic regulator
Functions which can be activated
Modulating temperature regulation with compensated set point:   
low temperature (Adjustment SET ±5 °C)   
medium temperature (Adjustment SET ±10 °C)
DHW exchanger preheating

Max. working pressure: primary 16 bar.                           
                                      secondary heating  3 bar.                           
                                      DHW circuit 10 bar.
Power supply: 230 V – 50 Hz
Power consumption: 75 W.