3D Viewer

RCA / RCA-V

Heat recovery unit

Manufacturer Fintek

These recuperators, constituted of 14 series, are used to regenerate heat in public rooms, like pub, meeting room, small and medium locals.

WORKING PRINCIPLES.
Inside hot air and outside cool air cross together but they don’t mix and mean while the hot of the inside defected air is being transferd to outside cool air. The efficiency of the recuperator in standard conditions (outside -5°C, inside 20°C with 50% of relative humidity) is always upper than 50%. The circular connections with exhaust and supply ducts can be fixed on each different side of the recuperator, to make easier the installation, for the RCA series.

FEATURES.
Painted and galvanized sheet steel case. Condense discharge drop tank. Acoustic insultation fire-retardant lining on the lower cover panel. Pleated filters. Efficiency F6-F7-F8-F9 as needed or requested. Backward blades impeller centrifugal fans with outside rotor (type RCA and RCA-V 300-550-800-1000-1400) singlephase. Forward blades, singlephase, centrifugal fan, directly coupled (type RCA and RCA-V 1800-2000-2600-3000-3500-4200-5500-6500-7000)

ACCESSORIES.
Electronic digital speed controller singlephase with 9 speed positions. - Electric battery series BAT - Cool or warm water battery to be included on request. - Other accessories- Electric control for CO2 filters

Dimensions

Gallery of close-ups

Related products

 - Heat recovery unit RCA-VT - Fintek Heat recovery unit These recuperators, constituted of 13 series, are used to regenerate heat in public rooms, like pub, meeting room, small and medium locals.

WORKING PRINCIPLES.
Inside hot air and outside cool air cross together but they don’t mix and mean while the hot of the inside defected air is being transferd to outside cool air. The efficiency of the recuperator in standard conditions (outside -5°C, inside 20°C with 50% of relative humidity) is always upper than 50%.

FEATURES.
Containment structure galvanized sheet steel, lined with acoustic insulation material exposed. Accommodated in n. 2 double inlet centrifugal fans which create the transmission air cross flow in exchange treated aluminium high-performance. Condense discharge drop tank,attack circular inlet and outlet Pleated filters efficiency G4 (standard) ,on request filtering cells F6 – F7 – F8 – F9 efficiency. Air-flow from 3000 to 18000 m /h, electric motors UNEL MEC series IP55 protection ‘F’ class Volt 230/400/50 Hz IE2 EFFICIENCY.

ACCESSORIES.
Electronic digital speed controller singlephase with 9 speed positions. - Electric battery BAT series - Cool or warm water battery to be included on request. - Other accessories - Electric control for CO filters.
 - Heat recovery unit RCA-BAT - Fintek Heat recovery unit These recuperators, constituted of 11 series, are used to regenerate heat in public rooms, like pub, meeting room, small and medium locals.

WORKING PRINCIPLES.
Inside hot air and outside cool air cross together but they don’t mix and mean while the hot of the inside defected air is being transferd to outside cool air. The efficiency of the recuperator in standard conditions (outside -5°C, inside 20°C with 50% of relative humidity) is always upper than 50%. The circular connections with exhaust and supply ducts can be fixed on each different side of the recuperator, to make easier the installation, for the RCA-BAT series.

FEATURES.
Containment structure galvanized sheet steel, lined with acoustic insulation material exposed. Circular connections inlet and outlet pleated filters efficiency G4 standard, on request filtering cells F6 - F7 - F8 - F9 efficiency. For the RCA-BAT 550 to the 1400 accommodated in n. 2 backward blades impellers centrifugal fans with outside rotor , instead for the RCA-BAT 1800 to the 5500 TD forward blades impellers double inlet centrifugal fans which create the transmission air cross flow in exchange treated aluminium high-performance, with the aid  of a hot water battery positioned within the post-heating recovery between the static exchanger and the fan. Air-flow range from 550 to 5500 m /h, volt 230/1F/50 Hz for RCA-BAT 4200 types, Volt 400/3F/50 Hz for the RCA-BAT 5500 TD.

ACCESSORIES.
Electronic digital speed controller singlephase with 9 speed positions. - Electric battery BAT series - Modular filter CFT - Other accessories - Electric control for CO2 filters - Inverter
 - Heat recovery unit RCA-DC / RCA-V-DC - Fintek Heat recovery unit These recuperators, constituted of 11 series, are used to regenerate heat in public rooms, like pub, meeting room, small and medium locals.

WORKING PRINCIPLES.
Inside hot air and outside cool air cross together but they don’t mix and mean while the hot of the inside defected air is being transferd to outside cool air. The efficiency of the recuperator in standard conditions (outside -5°C, inside 20°C with 50% of relative humidity) is always upper than 50%. The circular connections with exhaust and supply ducts can be fixed on each different side of the recuperator, to make easier the installation, for the RCA-DC series.

FEATURES.
Thanks to centrifugal fans BRUSHLESS-DC incorporated in the recuperators, we have excellent benefits and lower energy consumption but also aeraulic performances with constant pressure and airflow so to avoid the pressure drop due to clogging of the filters (F6 – F7 –F8 –F9) positioned inside or outside (CFT moduls). This due to the variable speed in automatic mode, using un integrated electronic system (PCF) that allows to control performances and consumption of the recuperator. Also this recuperator con be controlled by various sensors (CO2 –temperature – humidity – pc …)

ACCESSORIES.
Manual control - Automatic control INPUT 0-10 VDC - Electric battery BAT series - Cool and warm water battery to be included on request- Modular filter CFT - Outside roof - Electric control for CO2 filters - CO2 sensor temperature humidity

Fintek Catalogues

Heat recovery unit RCA / RCA-V - Fintek

Heat recovery unit RCA / RCA-V - Fintek
Heat recovery unit RCA / RCA-V - Fintek

Heat recovery unit RCA / RCA-V - Fintek
Heat recovery unit RCA / RCA-V - Fintek

Heat recovery unit RCA / RCA-V - Fintek
Heat recovery unit RCA / RCA-V - Fintek

Heat recovery unit RCA / RCA-V - Fintek
Heat recovery unit RCA / RCA-V - Fintek

Heat recovery unit RCA / RCA-V - Fintek
Heat recovery unit RCA / RCA-V - Fintek

Heat recovery unit RCA / RCA-V - Fintek
Heat recovery unit RCA / RCA-V - Fintek

Heat recovery unit RCA / RCA-V - Fintek
Loading Extra News
Loading event fair
Qr-code
Loading product info request form

Tags