ALDES OXYTONE PANNEAU 2012 Non-mechanical heat and smoke evacuator

ADD TO WISHLIST OR PROJECT
Overview

OXYTONE PANNEAU 2012 By ALDES

Type

Non-mechanical heat and smoke evacuator

Natural ventilation hse remote-controlled damper for smoke and heat extraction systems.‎ Dampers for natural smoke and heat evacuation in SENFC systems according to EN 12101-2
- Aluminium frame and panel
- Electromagnetic release (VM) or current interruption (VDS)at 24/48 VCC
- Manual reset
- Mechanical opening by means of two pistons on both vertical sides that disappear when the shutter is closed
- Aluminium frame and panel profiles for perfect integration on any window frame
- Central panel available in 3 versions
tempered double glazing with a 4/10/33 laminated surface.‎2
double glazing with thermal break 4/16 Ar/4 Climaplus
sandwich panel two outer surfaces in 20/10 aluminium 20 mm expanded polystyrene insulation
- The standard range extends from:
Height: 420 < Y < 1200 mm with a fabrication step of 5 mm
Width: 420 < L < 1600 mm with a fabrication step of 5 mm
If L≥1200 mm the damper is equipped with two electromagnetic release coils instead of one to ensure that the damper closes properly
- For other versions, e.‎g.‎ casement with internal opening, please consult us

FIELD OF APPLICATION
- Natural ventilation hse damper for smoke and heat evacuation systemsmechanical
- Natural smoke and heat exhaust damper in SENFC systems according to EN 12101-2

INSTALLATION
- Vertical installation on the external surface of a perimeter wall(opening towards the outside)
- It is also possible to install OXYTONE PANNEAU 2012 on curtain walls
- On the façade, the installation takes place at an angle between 0 and 5 degrees with respect to the vertical
- Possibility to install Oxytone Panneau 2012 towards the inside by means of a grilleGFAP 007 or GFAP for discreet aesthetic coverage
- The structure must be able to support the full weight of the damper on the side where the damper is hinged when the shutter is fully open
- Inside the wall the installation is carried out according to the diagram on the side and respecting the following installation methods
check that the plane where the shutter is installed is perfectly parallel to the ground
check the squareness of the frame
Number of vertical fixing points:
H < = 650 mm ➡ 1 central fixing
H > 650 mm ➡ 2 fixings at 250 mm both at the top and at the bottom

ACCESSORIES
- GFAP 007 internal grille
In the case of an installation inside a wall, the use of a GFAP 007 internal grille allows for discreet aesthetics.‎
The central part of the GFAP 007 grille fins is easily removable thanks to the 007 clips.‎
Selection of the GFAP 007 grille:
- X of the GFAP 007 = L - 50 mm
- Y of the GFAP 007 = H - 50 mm rounded off and not more than 25 mm
Fixing is carried out by application to the wall
- Installation accessories
- Cover for flush installation of the damper
- Protective cover for the damper's aesthetic finish
- 3 types of fixing kit
for wood, consisting of 8 screws
for metal, consisting of 8 screws
for concrete, consisting of 8 screws and dowels